We can produce high quality standardized or custom reverse osmosis products to meet a wide range of customer needs. And we also use world-leading membrane plates as raw materials to further ensure the performance of our products. With The product is widely used in household drinking water treatment plants with stable flux and high desalination rate.
Testing condition:
Testing sclution concentration– 2000 ppm
Test solution pH value一7.5
Recovery rate of single membrane element一15%
Testing temperature一 25℃
Testing pressure一225 psi (1.55 Mpa)
Operation Limits and Conditions:
Free Chlorine Tolerance一<0.1 ppm
Maximum feed water SDI5一5
pH range of feed water during continuous operation- 3~10
pH range of feed water during chemical cleaning 一2~12
Maximum feed water temperature一45°C
Maximum operating pressure一600 psi (4. 14 Mpa)
Maximum pressure drop of single element一15 psi (0.1 Mpa)
Maximum permeated flux一75 gpm (17 m2/h) (Model:8040) 16 gpm (3.6 m2/h) (Model: 4040)